EE4524 Design of Clean Energy System Assignment Questions 2026 | NTU
| University | Nanyang Technological University (NTU) |
| Subject | EE4524 Design of Clean Energy System |
EE4524 Assignment QuestionsÂ
Please read the following CAREFULLY before you submit the design report.
- Weightage of the design report: 50% of the total mark.
- Submit the PLECS simulation and design report to our course mailbox (EE4524A@gmail.com).
- Use your NTU email but not a private one (in case sent to the spam box).
- Submission deadline: Week 9, 11:59pm, 20 March 2026.
- Email subject line: EE4524 – Tutorial Group – Name, e.g., EE4524 – F11 – Wu Yang.
- Format of the report: PDF, name the file as EE4524 – Tutorial Group – Name; font style
Times New Roman; font size 12; max 5 pages; file size < 5 MB.
Question 1
A small wind turbine is connected to a permanent magnet synchronous generator that produces 30 kW power. This wind generator is operated at the unity power factor and connected to the grid through a three-phase back-to-back AC/DC/AC power converter. The generator output frequency is 35 Hz and the voltage is 200 V (phase rms). The grid frequency is 50 Hz and the voltage is 230 V (phase rms). The DC capacitance has a value of 5 mF, and the DC bus voltage Vdc is controlled at 800 V. The filter inductor has a value of 5 mH, and its internal equivalent series resistance (ESR) is 10 times the inductance value. The converter switching frequency is 20 kHz.
- Briefly discuss the functionality of the AC/DC/AC power converter in this wind generation system and the key components of this power converter. (20 Marks)
- Design a PI controller for current regulation in the dq rotating frame such that the time constant of the current loop is 1 ms. Briefly explain why abc to dq transformation is needed for inverter control. (10 Marks)
- Design another PI controller for DC voltage regulation such that the time constant of the voltage loop is 100 ms. Briefly explain why DC voltage control only determines the reference for id but not iq. (10 Marks)
- Build the PLECS simulation model that consists of the above power converter. (20 Marks)
Question 2
DC-DC converters are widely applied in data centers. Design a DC-DC converter for a data center server rack with input voltage Vin of 380 V and an output resistive load of 20 Ω. The filter inductor/capacitor you use will have an ESR of 10 times the inductor/capacitor value. The switching frequency is 50 kHz. The desired output voltage Vout range shall be 300-450 V (for students with even last digit in their matric no.), and250-500 V (for students with odd last digit in their matric no.).
- Choose a suitable topology and describe its operating principle. Derive the voltage gain (Vout / Vin) analytically using inductor voltage-second balance. (20 Marks)
- Build the PLECS simulation model that consists of the above power converter. Use cascaded PI controllers for voltage and current control loops. Present the waveform in
the report for tracking performance when the output voltage reference changes from its minimal value to its maximum value. (20 Marks)
[1] The output voltage could be inversed.
[2] Rigorous analysis is not required.
Get Your EE4524 Assignment Done Right—On Time, Every Time
Many students find the EE4524 Design of Clean Energy System Assignment challenging because it requires AC/DC/AC converter modelling, dq-frame PI controller design, DC-link control, DC-DC topology selection, analytical voltage gain derivation, and PLECS simulation implementation. But there is no need to worry, as My Assignment Help SG provides expert Power Electronics and Clean Energy Assignment Help aligned with Nanyang Technological University (NTU) guidelines. You can also explore our ntu assignment examples for structured academic support. Order today our sg assignment writing help and receive 100% custom, human-written technical assistance tailored to your simulation and report requirements.
- Social and New Media Written Report (40%): Website Message and Method Analysis with Strategic Recommendations | Murdoch
- ENG235 AIoT End-of-Course Assessment July 2026: PowerGrid SG Smart Grid and Utilities Case | SUSS
- BME363 ChatEHR End-of-Course Assessment July 2026: Large Language Models in Clinical Care | SUSS
- IBM380 International Business Capstone Management Project: Research Paper and Slide Presentation Brief (BBA)
- BUS329 Single Index Model Group Assignment TS 2026: Beta, Alpha and Risk Decomposition | Murdoch University
- Social and New Media Website Revamp Proposal: Digital Strategy Design Document | Murdoch
- Mentoring: Theory and Practice Essay: Collaboration in Mentoring Relationships | Kaplan
- NUR5731 Foundations of Integrated Care Thematic Literature Review 2026 | NUS
- LOG309 Industry 4.0 Logistics Applications ECA July 2026 | SUSS
- BUS304 Accounting Theory and Accountability Group Case Study TJA 2026 | Murdoch University