Posted on: 17th Sep 2025

QSM202 Construction Measurement (2 of 4) Architectural and M&E Works TMA-02 July 2025

Question 1

(a) Cite the relevant SMM clauses, illustrate with diagrams and examples the difference between measuring the general ceiling areas and the sides and soffit of suspended beams for:

i) In-situ finishes

(8 marks)

ii) Preformed tile finishes

( 8 marks)

(Note: Answers to include the reasons for the differences in approach to measurement)

(b) Explain and illustrate clearly with diagrams and examples how SMM clause 11.02f and 11.02g is applied when measuring timber plates and bearing timber in relation to the provision of joint allowances.

(Note: Student must illustrate and explain using different types of joints and timber lengths)

(14 marks)

Hire a Professional Essay & Assignment Writer for completing your Academic Assessments

Question 2

Figures Q2.1 to Q2.3 show the plan and section of a pitch tiled roof. Apply measurement techniques to take-off quantities for the following works:

(a) Roof coverings including associate underlays

(15 marks)

(b) Structural timber members including wall plates

(20 marks)

(c) Fascia, barge, soffit boards and timber bearers

(15 marks)

Specifications:

  1. Roof tiles shall be Hugenot HP 10 clay interlocking tiles with matching ridge, and eave tiles and fixed to 50 x 30 mm timber battens @ 300 mm c/c with galvanized nails.
  2. Roof tiles shall protrude from fascia board by 75 mm over the gutter.
  3. Special tiles shall be required at ridge, verges and eaves of roof.
  4. All roof timber shall be keruing preserved timber.
  5. Underlay shall comprise of two layers of bitumen felt overall 12 mm thick.
  6. Roof insulation shall be 50 mm thick fibre glass with double sided sisalation foil 450 and laid on fabric mesh 3325 to underside of roof covering.
  7. Pitch of roof is laid at 45 degrees slope.
  8. The first and last rafters shall be placed at 100 mm away from the brick gable end walls and spaced at 600 mm c/c
  9. Wall plates shall be placed on eaves brick walls between gable walls
  10. Ridge board shall be 75 x 300 mm thick
  11. Fascia board shall be 275 x 30 mm thick hard board.
  12. Barge board shall be 275 x 30 mm thick hard board
  13. Eaves soffit boards shall be installed at eaves and verges and shall be painted with three coats of enamel paint.
  14. Timber vertical and horizontal bearers shall be 300 mm long and install to support soffit boards at eaves and verges.
  15. All structural timbers shall be scarfed jointed except for wall plates (lap joints). All boards shall be butt jointed.
  16. All dimensions are in millimetres unless otherwise indicated.

Plan of Pitch Tiled Roof

Figure Q2.1: Plan of Pitch Tiled Roof

Section A-A of Pitch Tiled Roof

 

Figure Q2.2: Section A-A of Pitch Tiled Roof

Details at Ridge

Figure Q2.3: Details at Ridge

Buy Custom Answer of This Assessment & Raise Your Grades

Question 3

(a) Cite the various SMM clauses and explain the difference between measuring metal doors and frames versus timber doors and frames.

(12 marks)

(b) Apply measurement techniques and take off quantities for the metal door shown in

Figure Q3.1.

(8 marks)

Specifications:

  1. Metal door shall be 45mm thick single leaf, Hercules Tacam or other approved equivalent 4H blast resistant fire rated steel door complying with SS 332:2007
  2. Hardware shall be proprietary Tacam multi point lockset, heavy duty hinges, flush bolt and door handle.

Metal Door

Figure Q3.1: Metal Door

Metal Door Frame Detail

Figure Q3.2: Metal Door Frame Detail

 

—- END OF ASSIGNMENT —-

Stuck with a lot of homework assignments and feeling stressed ? Take professional academic assistance & Get 100% Plagiarism free papers

Get Help By Expert


Many students struggle with construction measurement assignments because they involve technical SMM clauses, diagrams, and accurate take-off methods. If you find tasks like roofing quantities, timber works, or finishes measurement challenging, expert help can make your work easier and error-free. At My Assignment Help SG, we provide thesis assignment help that is plagiarism-free, AI-free, and aligned with academic standards. For trusted support in architectural and M&E works, explore our professional assignment writing help Singapore today.

Tags:-
Answer
Financial Technologies and Innovations Assignment: Analyzing Block Inc.’s Fintech Promises, Challenges, and Ethical Considerations
No Need To Pay Extra
  • Turnitin Report

    $10.00
  • Proofreading and Editing

    $9.00
    Per Page
  • Consultation with Expert

    $35.00
    Per Hour
  • Live Session 1-on-1

    $40.00
    Per 30 min.
  • Quality Check

    $25.00
  • Total
    Free

New Special Offer

Get 30% Off

Hire an Assignment Helper and Earn A+ Grade

UP TO 15 % DISCOUNT

Get Your Assignment Completed At Lower Prices

Plagiarism Free Solutions
100% Original Work
24*7 Online Assistance
Native PhD Experts
Hire a Writer Now
My Assignment Help SG Services
My Assignment Help SG

Rated 4.9/5 Based on 22945 Singaporean Students